LAB Ultrapure Water System

RO pure water: desalination rate as high as 95-99% , Conductivity ≤10μS/cm

Ultrapure water:

  • Resistivity 18.25MΩ.cm@25°C,
  • TOC: <3 ppb,
  • particles (>0.22 um) <1/ml,
  • microorganism <1 cfu/ml,
  • pyrogen<0.001EU/ml,
  • RNases≤0.01ng/ml,
  • DNases≤3Pg/ul
Feature
  • Colored touched screen, humanized operation interface make users completely monitor controller’s working status and real-time data.
  • ABS engineering plastic case, powder coating technology, with water quality and quantity upgrading function, self-priming door.
  • Type U Korean quick-insert filters, used imported filtering materials.
  • Upgraded self-cleaning filter which with design of built-in 10’’ 10μm stainless steel filter mesh and silicone soft scraping, it can clean anytime, perfectly replace PP cotton filter, no need exchange.
  • Long-acting KDF filter whose adsorption efficiency and lifetime are more than 10 times as equal quantity activated carbon filter’s, this avoid frequent filter replacement.
  • Imported UF ultra filtration column ensure meet request for removing pyrogen and RNA.
  • Built-in pressure tank which has inner pouch whose material is anti-bacteria and it is transparent, the inner pouch can be changed anytime.
  • Inbuilt feed water pressure test gauge to real time monitor tap water pressure and filters blocking.
  • Lifetime of PP cotton, activated carbon filter, RO membrane and ultra purification columns can be set to display the elapsed&rest time of consumables. Automatic reminder for filter replacement to avoid water quality decreasing.
  • Perfect managing functions of RO&UP water making, circulation system and sterilization.
  • Feed water, RO and UP water three ways water quality sensor and five ways switches signal are accessed integrated, with functions of timing quantitative water taking.
  • Equipped with USB Host interface, it supports data export function of historical alarm record and historical water intake record.
  • Low-voltage 24VDC is used as the main power supply, which meets the safety regulations and meets the requirements of humid environment, and will not cause personal injury.
  • Can be with inner circulation system to ensure water quality keep at the highest level. ( optional)
Application

Applicable to all kinds of physical and chemical detection, biochemical analysis, blood examination, micro analysis, washing, HPLC, IC, GC, analytical experiments.

Process
Filter function
  • Front filter: 10 micron mesh 316 stainless steel washable filter, remove minor impurities,extend PP cotton lifetime.
  • KDF filter: Remove residual chlorine,heavy metals, retrain fungi breed, lifetime is very long, can protect post-positive filters.
  • PP: PP cotton filter, remove impurities (greater than 5 micron) such as suspended solid, rust, sludge, colloid, etc.
  • AC: Granular activated carbon filter: remove color, odor, residual chlorine and heavy metals
  • RO: Reverse osmosis membrane: filter out <1nm pollutants, ions, particles
  • UV: UV germicidal lamp: sterilization device, decomposition and photo oxidation OC, lower TOC
  • UP: Ultra-purification column: ion exchange resin bed, H+ and OH– ion removal
  • UF: Ultra filtration membrane: remove pyrogen, RNase, DNase
  • TF: 0.2μm terminal filter, final removal for < 0.2μm bacteria
Specification
Model LAB-UP LAB-UP-F LAB-UP-V LAB-UP-VF
Type classification Standard Low Endotoxin Low TOC Comprehensive
Output 10/20/30 L/H
Water requirements Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃
RO Water Parameter
Ion rejection rate 97%-99% (when using a new RO membrane)
Organic matter rejection rate >99% when MW>200 Dalton
Particle and bacterial rejection > 99%
Application Front system of ultra-pure water machine, buffer configuration, photosensitive film washing, water supply for stability experiment box, meteorological experiment equipment, hydrogen generator, battery adding liquid, electroplating and other instruments
UP Water Parameter (ASTM TYPE I Grade Water)
Resistivity (25℃) 18.25 M Ω. Cm @ 25 ℃
Heavy metal ion < 0.01 ppb
Total organic carbon (TOC) * <10 ppb <3 ppb
bacteria < 1 cfu/ml * (with terminal filter)
Particulate matter (> 0.1 microns) <1/ml
Pyrogen (endotoxin) N/A < 0.001 Eu/ml N/A < 0.001 Eu/ml
Ribonuclease (RNases) N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases N/A <5pg/ml N/A <5pg/ml
Application All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, experiment High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing
Electrical requirements 100-240V, 50/60Hz, 48-72W
The system configuration Host machine (including 1 set of purification column)+8 L built-in pressure water storage tank +TDS pen + accessory bag
Consumables
No Filter element Replace Cycle Remark
1 KDF composite filter About 1 year  
2 11″ PP filter About 4-6 month
3 11″ activated carbon filter About 4-6 month
4 75 GPD RO membrane About 1-2 years
5 100 GPD RO membrane About 1-2 years
6 11″ ultra-purification column (imported resin) About 1000 liter
7 0.2 μm imported PES terminal filter About 2-3 years
8 Dual wavelength (185 & 254 nm) UV lamp tube (import) About 9000 hours
9 Imported PES 5000 Dalton UF heat source column /