PRO-S Ultrapure Water System

RO pure water: desalination rate as high as 95-99% , Conductivity ≤10μS/cm
Ultrapure water:
resistivity 18.25MΩ.cm@25°C,
TOC: <3 ppb,
particles (>0.22 um) <1/ml,
microorganism <1 cfu/m,
pyrogen<0.001EU/ml,
RNases≤0.01ng/ml,
DNases≤3Pg/ml/ul

Feature
  • Backlight Touch LCD display.
  • Dual water quality online monitoring, display RO water conductivity and UP or DI water resistance at the same time, also show machine operation status.
  • Menu-type operation, parameters can be set and modified, operating status display and indication light indicate to promptly reflect machine operating status such as  high-pressure shutdown, low-pressure alarm, water full shutdown, etc.
  • Alarming for water quality exceeding, automatic filters replacement reminding, water intake time can be set. Take water by touched key, Automatic indication light indicate RO and UP water intake.
  • Fully automatic microcomputer control display real-time monitor power source, water lack, water making, water fulling, flushing, strong flushing control.
  • Floor type, with mobile&fixed trundle at the bottom to make installation and moving much more convenient.
  • 2 water outlets: RO and UP water
  • Multiple security protection, beautiful and exquisite machine appearance.
  • With TDS water quality test pen presented
  • Equipped with large capacity purification tank.
Application

Applicable to all kinds of physical and chemical detection, biochemical analysis, blood examination, micro analysis, washing, HPLC, IC, GC, analytical experiments.

Process
Filter function
PP cotton filter remove impurities (greater than 5 micron) such as suspended solid, rust, sludge, colloid, etc.
Granular activated carbon filter remove color, odor, residual chlorine and heavy metals
Reverse osmosis membrane filter out <1nm pollutants, ions, particles
Ultra-purification tank&column ion exchange resin bed, H+ and OHion removal
Dual wavelength  UV lamp  sterilization device, decomposition and photo oxidation OC, lower TOC  (*-V,-VF)
Ultra filtration membrane remove pyrogen, RNase, DNase(*-F,-VF)
0.2μm terminal filter final removal for < 0.2μm bacteria
Specification
Model PRO-S-UP PRO-S-UP-F PRO-S-UP-V PRO-S-UP-VF
Type classification Standard Low Endotoxin Low TOC Comprehensive
Output 45/60/90/120 L/H
Water requirements Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃, TDS<200ppm
RO Water Parameter
Ion rejection rate 97%-99% (when using a new RO membrane)
Organic matter rejection rate >99% when MW>200 Dalton
Particle and bacterial rejection > 99%
Application Front system of ultra-pure water machine, buffer configuration, photosensitive film washing, water supply for stability experiment box, meteorological experiment equipment, hydrogen generator, battery adding liquid, electroplating and other instruments
UP Water Parameter (ASTM TYPE I Grade Water)
Resistivity (25℃) 18.25 M Ω. Cm @ 25 ℃
Heavy metal ion < 0.01 ppb
Total organic carbon (TOC) * <10 ppb <3 ppb
bacteria < 1 cfu/ml * (with terminal filter)
Particulate matter (> 0.1 microns) <1/ml
Pyrogen (endotoxin) N/A < 0.001 Eu/ml N/A < 0.001 Eu/ml
Ribonuclease (RNases) N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases N/A <5pg/ml N/A <5pg/ml
Application All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, experiment High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing
Electrical requirements 100-240V, 50/60Hz, 48-72W
The system configuration Host machine (including 1 set of purification column) + 40/60L pressure water tank +TDS pen + accessory bag
Consumables
No Filter element Replace Cycle Remark
1 20″ PP cotton filter About 4-6 month
2 20″ Refined activated carbon filter About 4-6 month
3 400 GPD RO membrane About 1-2 years
600 GPD RO membrane About 1-2 years
4 12L ultra purified tank About 25 tons
11″ ultra-purification column (imported resin)
5 0.2 μm imported PES terminal filter About 2-3 years
6 Dual wavelength (185 & 254 nm) UV lamp tube (import) About 9000 hours
7 Imported PES 5000 Dalton UF heat source column /

Related suggestion

Request for quotation

Name *
Fill out this field
E-mail *
Please enter a valid email address.
Phone *
Fill out this field
Country
Fill out this field
Company name
Fill out this field
Leave a message *
Fill out this field