STAR Ultrapure Water System

RO pure water: desalination rate as high as 95-99% , Conductivity ≤10μS/cm
Ultrapure water:
resistivity 18.25MΩ.cm@25°C,
TOC: <3 ppb,
particles (>0.22 um) <1/ml,
microorganism <1 cfu/ml,
pyrogen<0.001EU/ml,
RNases≤0.01ng/ml,
DNases≤3Pg/ul

Feature
  • The case adopts ABS plastic spraying process; the appearance adopts curve design to be more beautiful and generous with removable drain tank
  • All Korean-style quick-inserted filter columns in the entire system are built into the chassis; easy maintenance and replacement;
  • Water quality online monitoring system, which can measure the water quality of the produced water immediately;
  • Equipped with a portable TDS pen, which can test TDS content, conductance and water temperature anytime and anywhere;
  • Touch the keys, two water quality, ready to use;
  • Touch the door to open the door design, the replacement of the filter element is simple and fast, the entire process does not require any tools, and the filter element replacement is easily completed;
  • Support WIFI expansion interface, provide mobile APP remote monitoring function, improve user experience; (optional)
  • Chinese LCD display and user-friendly operation interface allow you to fully monitor the working status and real-time data of the controller;
  • Four user passwords and factory password protection;
  • Perfect RO pure water and ultra pure water to make water, system water extraction, system flushing and other functions.
  • Perfect raw water pressure display, no water protection, high pressure water full protection functions and fault alarm function.
  • Complete consumable life management function, support the unique ID identification function of consumables, and eliminate counterfeit and inferior non-original consumables. (Optional)
  • It adopts low-voltage 24VDC as the main power supply, which complies with the safety regulations and meets the use in humid environments without causing harm to people.
Application

Suitable for molecular biology, life sciences, genetic research, cell culture, amino acid analysis, protein purification, toxicology research, drug development, medical testing

Process
Filter function
  • Front filter: 10 micron mesh 316 stainless steel washable filter, remove minor impurities,extend PP cotton lifetime.
  • KDF filter: Remove residual chlorine,heavy metals, retrain fungi breed, lifetime is very long, can protect post-positive filters.
  • PP: PP cotton filter, remove impurities (greater than 5 micron) such as suspended solid, rust, sludge, colloid, etc.
  • AC: Granular activated carbon filter: remove color, odor, residual chlorine and heavy metals
  • RO: Reverse osmosis membrane: filter out <1nm pollutants, ions, particles
  • UV: UV germicidal lamp: sterilization device, decomposition and photo oxidation OC, lower TOC
  • UP: Ultra-purification column: ion exchange resin bed, H+ and OH– ion removal
  • UF: Ultra filtration membrane: remove pyrogen, RNase, DNase
  • TF: 0.2μm terminal filter, final removal for < 0.2μm bacteria
Specification
Model STAR-UP STAR-UP-F STAR-UP-V STAR-UP-VF
Type classification Standard Low Endotoxin Low TOC Comprehensive
Output 10/20/30 L/H
Water requirements Urban tap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃
RO Water Parameter
Ion rejection rate 97%-99% (when using a new RO membrane)
Organic matter rejection rate >99% when MW>200 Dalton
Particle and bacterial rejection > 99%
Application Front system of ultra-pure water machine, buffer configuration, photosensitive film washing, water supply for stability experiment box, meteorological experiment equipment, hydrogen generator, battery adding liquid, electroplating and other instruments
UP Water Parameter (ASTM TYPE I Grade Water)
Resistivity (25℃) 18.25 M Ω. Cm @ 25 ℃
Heavy metal ion < 0.01 ppb
Total organic carbon (TOC) * <10 ppb <3 ppb
bacteria < 1 cfu/ml * (with terminal filter)
Particulate matter (> 0.1 microns) <1/ml
Pyrogen (endotoxin) N/A < 0.001 Eu/ml N/A < 0.001 Eu/ml
Ribonuclease (RNases) N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases N/A <5pg/ml N/A <5pg/ml
Application All kinds of physical and chemical testing, biochemical analysis, blood examination, microanalysis, flushing special, HPLC, IC, GC, experiment High sensitivity ICP/MS, PCR, PPT level analysis, isotope analysis, molecular biology, life science, CDC, drug control institute, quality inspection institute Atomic absorption/emission spectrometry, mass spectrometry, TOC detection, environmental monitoring, biochip development, trace organic matter analysis Molecular biology, Life sciences, gene research, cell culture, amino acid analysis, protein purification, toxicology, drug development, medical testing
Electrical requirements 100-240V, 50/60Hz, 48-72W
The system configuration Host machine (including 1 set of purification column)+ 12L pressure water tank +TDS pen + accessory bag
Consumables
No. Filter element Replace Cycle Remark
1 11″ PP filter About 4-6 month
2 11″ activated carbon filter About 4-6 month
3 75 GPD RO membrane About 1-2 years
4 100 GPD RO membrane About 1-2 years
5 11″ ultra-purification column (imported resin) About 1000 liter
6 0.2 μm PES terminal filter About 2-3 years
7 Imported 5000 Dalton UF heat source column ——
8 Dual wavelength (185 & 254 nm) UV lamp (import) About9000 hours